An item actuated by an external magnetic field and having two or more contacts inclosed in a sealed capsule. Do not use if switch has an actuator, such as a lever, push button, toggle, and the like. See SWITCH (as modified). For items provided with an operating coil, use RELAY (as modified). It includes items in which a contact may be moved into a mercury pool by a magnetic field.
NAMEDITEM NAME
NOUN, WITH OR WITHOUT MODIFIERS, BY WHICH AN ITEM OF SUPPLY IS KNOWN.
Enter the item name code.
(NAMED28945*)
CRLD*JNONPILE-UP CONTACT ARRANGEMENT
THE DESIGNATION THAT IDENTIFIES THE ELECTRICAL CONFIGURATION OF A NONPILE-UP CONTACT GROUP INCLUDING THE NUMBER OF SWITCHING POLES OR FORMS.
Enter the applicable ISAC from Table 1 below followed by the mode code, applicable Reply Code from Table 2 below followed by a numeric reply with a minimum of one digit.
(CRLD3AEEJAB2*;CRLD3AEEJAB2$$JAB3*;CRLD3AEEJAB2$JAB2*)
| Table 1 |
| ISAC Field Indicator (5000) | Location |
| 3AEE | OVERALL |
| 3AMP | FIRST SWITCH UNIT |
| 3AMZ | SINGLE SWITCH UNIT |
| 3HOU | LOCATION NOT OTHERWISE SPECIFIED |
| Table 2 |
| Reply Code (AG28) | Reply |
| BB | FOUR THROW, DOUBLE MAKE, NORMALLY OPEN, MOMENTARY ACTION |
| BA | FOUR THROW, NORMALLY OPEN, MOMENTARY ACTION |
| BC | FOUR WAY |
| AH | POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| AL | POLE, DOUBLE THROW, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY |
| AJ | POLE, DOUBLE THROW, DOUBLE BREAK/DOUBLE MAKE, PERMANENT JUMPER, BOTH POSITIONS MAINTAINED |
| AM | POLE, DOUBLE THROW, DOUBLE BREAK/DOUBLE MAKE, PERMANENT JUMPER, ONE POSITION MOMENTARY |
| AK | POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| AP | POLE, DOUBLE THROW, ONE POSITION MOMENTARY, TWO POSITIONS MAINTAINED |
| AR | POLE, DOUBLE THROW, PERMANENT INTERNAL JUMPERS, BOTH POSITIONS MAINTAINED |
| AN | POLE, DOUBLE THROW, THREE POSITIONS MAINTAINED |
| AQ | POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY |
| AA | POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
| AB | POLE, SINGLE THROW, DOUBLE MAKE, BOTH POSITIONS MAINTAINED |
| CB | POLE, SINGLE THROW, DOUBLE MAKE, BOTH POSITIONS MAINTAINED, WITH CONTACT ON ARM |
| AC | POLE, SINGLE THROW, DUAL CONTACT, BOTH POSITIONS MAINTAINED |
| AG | POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION |
| CG | POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION, WITH CONTACT ON ARM. |
| AF | POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| AE | POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| CE | POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION, WITH CONTACT ON ARM |
| AD | POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| AS | TWO CIRCUIT, BOTH POSITIONS MAINTAINED |
| AT | TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, BOTH POSITIONS MAINTAINED |
| AW | TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY |
| AU | TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, PERMANENT JUMPER WITH NO EXTERNAL TERMINAL, BOTH POSITIONS MAINTAINED |
| AX | TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, PERMANENT JUMPER WITH NO EXTERNAL TERMINAL, ONE POSITION MOMENTARY |
| AZ | TWO CIRCUIT, DOUBLE MAKE, TWO POSITIONS MOMENTARY |
| AV | TWO CIRCUIT, ONE POSITION MOMENTARY |
| AY | TWO CIRCUIT, TWO POSITIONS MOMENTARY |

Reference NotesRefer to Reference Drawings for assitance in answering this MRC.
CQDK*APILE-UP CONTACT FORM ARRANGEMENT
THE BASIC CONTACT FORMS,IN THE ORDER OF ASSEMBLAGE,THAT COLLECTIVELY DESCRIBE THE SWITCHING STRUCTURE OF A PILE-UP CONTACT GROUP.
Enter the applicable ISAC from the table below followed by the mode code, followed by a alpha-numeric reply with a minimum of one character.
(CQDK3AEEAH6)
| Table 1 |
| ISAC Field Indicator (5000) | Location |
| 3AEE | OVERALL |
| 3ANK | SINGLE POSITION |
| 3HOU | LOCATION NOT OTHERWISE SPECIFIED |

Reference NotesRefer to Reference Drawings for assitance in answering this MRC.
AFXEJMAXIMUM VOLTAGE RATING IN VOLTS
THE MAXIMUM VOLTAGE RATING AT WHICH THE ITEM IS DESIGNED TO OPERATE IN AN ALTERNATING CURRENT AND/OR DIRECT CURRENT CIRCUIT,EXPRESSED IN VOLTS.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFXEJC2.0*;AFXEJC2.0$JC2.0*;AFXEJC2.0$$JC2.1*)
| Table 1 |
| Reply Code (AE16) | Reply |
| B | AC |
| C | DC |
CXQRJCONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE
THE AMOUNT OF CURRENT THE CONTACTS ARE RATED TO MAKE OR BREAK AT MAXIMUM RATED VOLTAGE,WITH A SPECIFIED LOAD.
Enter the applicable Reply Code from Tables 1 & 2 & 3 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(CXQRJAAMC2.0*;CXQRJAAMC2.0$$JAAMC2.1*)
| Table 1 |
| Reply Code (AC30) | Reply |
| A | AMPERES |
| L | MILLIAMPERES |
| Table 2 |
| Reply Code (AK53) | Reply |
| AD | INDUCTIVE |
| AL | LAMP |
| AM | MOTOR |
| AC | RESISTIVE |
| Table 3 |
| Reply Code (AE16) | Reply |
| B | AC |
| C | DC |
IF STYLE/REPLY CODE(s) 1L, 2L, 3L OR 4L WERE ENTERED FOR MRC AAQL, YOU MUST ANSWER MRC (ADAQ and ABPM)
IF STYLE/REPLY CODE(s) 5L WERE ENTERED FOR MRC AAQL, YOU MUST ANSWER MRC (ADAT and ADAQ and ABPM)
AAQLLBODY STYLE
THE STYLE DESIGNATION INDICATING THE CONFIGURATION THAT MOST NEARLY CORRESPONDS TO THE APPEARANCE OF THE BODY.
Review the representative drawings below, find the drawing which best represents your item.Use the Physical Drawing ID (eg: AAT1001) to identify the row(s) in the table which are applicable to your drawing.Enter the applicable reply code from the table below.
(AAQLL5L)
| Table 1 |
| Physical Drawing ID | Reply Code (STYL) | Reply |
| AN10135 | 1L | UNCASED |
| AN10136 | 2L | UNCASED |
| AN10137 | 3L | UNCASED |
| AN10139 | 4L | UNCASED |
| AN10138 | 5L | T-SHAPE |
ABKQ*JCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
THE DISTANCE BETWEEN THE CENTER OF ONE MOUNTING FACILITY AND THE CENTER OF THE ADJACENT MOUNTING FACILITY PARALLEL TO THE LENGTH.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABKQJAC2.0*;ABKQJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABKR*JCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
THE DISTANCE BETWEEN THE CENTER OF ONE MOUNTING FACILITY AND THE CENTER OF THE ADJACENT MOUNTING FACILITY PARALLEL TO THE WIDTH.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABKRJAC2.0*;ABKRJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABPM*JBODY DIAMETER
THE LENGTH OF A STRAIGHT LINE WHICH PASSES THROUGH THE CENTER OF THE BODY,AND TERMINATES AT THE CIRCUMFERENCE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABPMJAB2.0*;ABPMJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABXD*JBUSHING LENGTH
A MEASUREMENT OF THE LONGEST DIMENSION OF A BUSHING,IN DISTINCTION FROM WIDTH.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABXDJAC2.0*;ABXDJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ADAQ*JBODY LENGTH
A MEASUREMENT OF THE LONGEST DIMENSION OF THE BODY,IN DISTINCTION FROM WIDTH.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ADAQJAA2.0*;ADAQJAA2.0$$JAA2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ADAT*JBODY WIDTH
A MEASUREMENT TAKEN AT RIGHT ANGLES TO THE LENGTH OF THE BODY,IN DISTINCTION FROM THICKNESS.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ADATJAC2.0*;ADATJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ADAU*JBODY HEIGHT
A MEASUREMENT FROM THE BOTTOM TO THE TOP OF THE BODY,IN DISTINCTION FROM DEPTH.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ADAUJAA2.0*;ADAUJAA2.0$$JAA2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AEBW*JCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT
THE DISTANCE BETWEEN THE CENTER OF ONE MOUNTING FACILITY AND THE CENTER OF THE ADJACENT MOUNTING FACILITY PARALLEL TO THE HEIGHT.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AEBWJAA2.0*;AEBWJAA2.0$$JAA2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AEBX*JCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO DIAMETER
THE DISTANCE BETWEEN THE CENTER OF ONE MOUNTING FACILITY AND THE CENTER OF THE ADJACENT MOUNTING FACILITY PARALLEL TO THE DIAMETER.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AEBXJAB2.0*;AEBXJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AEHT*JCENTER TO CENTER DISTANCE BETWEEN TERMINALS
THE CENTER TO CENTER DISTANCE BETWEEN TERMINALS.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AEHTJAC2.0*;AEHTJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AFUN*JCENTER TO CENTER DISTANCE BETWEEN COVER PLATE MOUNTING HOLES
NONE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFUNJAB2.0*;AFUNJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AFWB*JHOUSING DIAMETER
THE LENGTH OF A STRAIGHT LINE WHICH PASSES THROUGH THE CENTER OF THE HOUSING, AND TERMINATES AT THE CIRCUMFERENCE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFWBJAA2.0*;AFWBJAA2.0$$JAA2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AFWC*JHOUSING HEIGHT
NONE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFWCJAB2.0*;AFWCJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AFWD*JHOUSING LENGTH
A MEASUREMENT OF THE LONGEST DIMENSION OF THE HOUSING,IN DISTINCTION FROM WIDTH.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFWDJAB2.0*;AFWDJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AFWE*JHOUSING WIDTH
A MEASUREMENT TAKEN AT RIGHT ANGLES TO THE LENGTH OF A HOUSING,IN DISTINCTION FROM THICKNESS.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFWEJAB2.0*;AFWEJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AFWF*JHOUSING BUSHING LENGTH
NONE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFWFJAB2.0*;AFWFJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AFWG*JCENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO HEIGHT
NONE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFWGJAB2.0*;AFWGJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AFWH*JCENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO LENGTH
NONE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFWHJAC2.0*;AFWHJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AFWJ*JCENTER TO CENTER DISTANCE BETWEEN HOUSING MOUNTING FACILITIES PARALLEL TO WIDTH
NONE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFWJJAB2.0*;AFWJJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
AJWX*JMOUNTING SURFACE TO TERMINAL END DISTANCE
NONE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AJWXJAC2.0*;AJWXJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
CWYZ*JCENTER TO CENTER DISTANCE BETWEEN MOUNTING SUPPORT AND NEAREST TERMINAL
NONE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(CWYZJAA2.0*;CWYZJAA2.0$$JAA2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
ABHP*JOVERALL LENGTH
THE DIMENSION MEASURED ALONG THE LONGITUDINAL AXIS WITH TERMINATED POINTS AT THE EXTREME ENDS OF THE ITEM.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABHPJAC2.0*;ABHPJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |

Reference NotesRefer to Reference Drawings for assitance in answering this MRC.
ABMK*JOVERALL WIDTH
AN OVERALL MEASUREMENT TAKEN AT RIGHT ANGLES TO THE LENGTH OF AN ITEM,IN DISTINCTION FROM THICKNESS.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABMKJAB2.0*;ABMKJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |

Reference NotesRefer to Reference Drawings for assitance in answering this MRC.
ABKW*JOVERALL HEIGHT
THE DISTANCE MEASURED IN A STRAIGHT LINE FROM THE BOTTOM TO THE TOP OF AN ITEM.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ABKWJAC2.0*;ABKWJAC2.0$$JAC2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |

Reference NotesRefer to Reference Drawings for assitance in answering this MRC.
ADAV*JOVERALL DIAMETER
A MEASUREMENT OF THE LONGEST STRAIGHT LINE ACROSS A CIRCULAR CROSS-SECTIONAL PLANE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(ADAVJAA2.0*;ADAVJAA2.0$$JAA2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |

Reference NotesRefer to Reference Drawings for assitance in answering this MRC.
TTQYJTERMINAL TYPE AND QUANTITY
INDICATES THE TYPE AND NUMBER OF TERMINALS FOR PROVIDING ELECTRICAL CONNECTION.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit.
(TTQYJAAM2*;TTQYJAAM2$$JAAM3*;TTQYJAAM2$JAAM2*)
| Table 1 |
| Reply Code (AN89) | Reply |
| ABL | BINDING POST |
| AEM | BUS BAR |
| AEP | CABLE W/CONNECTOR |
| ADB | CLIP |
| AEB | COMPRESSION |
| ACN | CONNECTOR, PLUG |
| AAF | CONNECTOR, RECEPTACLE |
| AFL | CRIMP |
| AJT | ELECTRON TUBE BASE |
| AAM | PIN |
| ACR | PRINTED CIRCUIT |
| ADA | QUICK DISCONNECT, FEMALE |
| ACZ | QUICK DISCONNECT, MALE |
| ABQ | SCREW |
| AEL | SOCKET, INTEGRATED WIRE TERMINATION |
| AAS | SOLDER STUD |
| AEK | SOLDERLESS LUG |
| AEN | SPRING |
| ABX | TAB W/SCREW |
| ABB | TAB, SOLDER LUG |
| ABD | THREADED STUD |
| ACB | TURRET |
| ACM | WIRE HOOK |
| ACC | WIRE LEAD |
| ACD | WIRE LOOP |
| AFM | WIRE WRAP |

Reference NotesRefer to Reference Drawings for assitance in answering this MRC.
CSJN*JSWITCH ACTUATING FORCE
THE AMOUNT OF FORCE REQUIRED TO ACTUATE THE SWITCH.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(CSJNJDC2.0*;CSJNJDC2.0$$JDC2.1*)
| Table 1 |
| Reply Code (AA56) | Reply |
| C | AMPERE-TURNS |
| D | CENTIMETER-GRAMS |
| E | GRAMS |
| A | INCH-OUNCES |
| W | NEWTONS |
| H | OUNCES |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
CRRM*JSWITCH RELEASE FORCE
THE AMOUNT TO WHICH THE ACTUATING FORCE MUST BE REDUCED TO PERMIT THE SWITCH TO BECOME UNACTUATED.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(CRRMJWC2.0*;CRRMJWC2.0$$JWC2.1*)
| Table 1 |
| Reply Code (AA56) | Reply |
| C | AMPERE-TURNS |
| D | CENTIMETER-GRAMS |
| E | GRAMS |
| A | INCH-OUNCES |
| W | NEWTONS |
| H | OUNCES |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
IF STYLE/REPLY CODE(s) ACQ WERE ENTERED FOR MRC AXGY, YOU MUST ANSWER MRC (AEBV)
AXGYDMOUNTING METHOD
THE MEANS OF ATTACHING THE ITEM.
Enter the applicable reply code from the table below
(AXGYDAET*;AXGYDAJR$$DABC*)
| Table 1 |
| Reply Code (AM39) | Reply |
| ABB | BASE |
| ABC | BRACKET |
| AFL | CLIP |
| ACR | FLANGE |
| AGQ | FLUSH |
| ABL | FRICTION |
| AGR | HANGER |
| AGT | INSIDE ROD |
| AAB | INTEGRAL |
| AGH | INTERNAL THREAD |
| AHH | MALE PRONG |
| AED | PANEL |
| ADC | PRESS FIT |
| AEZ | PRINTED CIRCUIT |
| AHK | RETAINING PLATE |
| ABW | SCREW |
| AGY | SCREW CLAMP |
| AGZ | SCREW LOCK |
| AAF | SETSCREW |
| ABY | SLOT |
| AHB | SPRING CONTACT |
| AJR | STRUT |
| AAE | STUD |
| AHC | SWEATED |
| ACD | TERMINAL |
| AFA | THREADED BUSHING |
| AJZ | THREADED BUSHING W/PANEL SEAL |
| AHF | THREADED HOLE |
| AET | THREADED STUD |
| BTW | UNTHREADED BUSHING |
| ACQ | UNTHREADED HOLE |
AEBV*JUNTHREADED MOUNTING HOLE DIAMETER
THE LENGTH OF A STRAIGHT LINE WHICH PASSES THROUGH THE CENTER OF AN UNTHREADED MOUNTING HOLE,AND TERMINATES AT THE CIRCUMFERENCE.
Enter the applicable Reply Code from Tables 1 & 2 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AEBVJAB2.0*;AEBVJAB2.0$$JAB2.1*)
| Table 1 |
| Reply Code (AA05) | Reply |
| A | INCHES |
| L | MILLIMETERS |
| Table 2 |
| Reply Code (AC20) | Reply |
| A | NOMINAL |
| B | MINIMUM |
| C | MAXIMUM |
CBBL*DFEATURES PROVIDED
THOSE FEATURES,NOT OTHERWISE SPECIFIED,WHICH MAY BE REQUIRED FOR PROPER FUNCTIONING OF THE ITEM.
Enter the applicable reply code from the table below
(CBBLDAGM*;CBBLDDAU$$DADM*)
| Table 1 |
| Reply Code (AN47) | Reply |
| AGK | ACTUATOR SEAL |
| ASQ | ADJUSTABLE |
| AGL | CARTRIDGE FUSEHOLDER |
| ADM | ELECTRICAL ACCESS PORT |
| DAS | FOUR-WAY SPLIT LENS |
| DAT | FULL DISPLAY LENS |
| CFB | HOLDING MECHANISM |
| AGM | HOLDING SOLENOID |
| DAU | HORIZONTAL SPLIT LENS |
| BLH | LAMP HOLDER |
| AAJ | MOUNTING HARDWARE |
| AGN | NEUTRAL TERMINAL |
| DAV | NONADJUSTABLE |
| AJK | NONTURN FEATURE |
| AGA | O RING |
| AGP | PLUG FUSEHOLDER |
| AJP | REMOVABLE LIGHT FILTER |
| AGQ | RFI SHIELDING |
| DAW | THREE-WAY SPLIT LENS |
| ANF | VARIABLE RESISTOR |
| DAX | VERTICAL SPLIT LENS |
FEAT*GSPECIAL FEATURES
THOSE UNUSUAL OR UNIQUE CHARACTERISTICS OR QUALITIES OF AN ITEM NOT COVERED IN THE OTHER REQUIREMENTS AND WHICH ARE DETERMINED TO BE ESSENTIAL FOR IDENTIFICATION ON ONE OR MORE OTHER FUNCTIONS.
Enter the reply in clear text. Separate multiple replies with a semicolon.
(FEATGADJUSTABLE NOSE CLIP*; FEATGADJUSTABLE NOSE PIECE; DISPOSABLE*)
TEST*JTEST DATA DOCUMENT
THE SPECIFICATION,STANDARD,DRAWING,OR SIMILAR INSTRUMENT THAT SPECIFIES ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS OR TEST CONDITIONS UNDER WHICH AN ITEM IS TESTED AND ESTABLISHES ACCEPTABLE LIMITS WITHIN WHICH THE ITEM MUST CONFORM IDENTIFIED BY AN ALPHABETIC AND/OR NUMERIC REFERENCE NUMBER. INCLUDES THE COMMERCIAL AND GOVERNMENT ENTITY (CAGE) CODE OF THE ENTITY CONTROLLING THE INSTRUMENT.
Enter the applicable Reply Code from the table below, followed by the 5-position CAGE Code, a dash, and the document identification number.
(TESTJA12345-CWX654321*; TESTJA1234A-654321$$JB5556A-663654*; TESTJAA2345-654321$JB55566-663654*)
| Table 1 |
| Reply Code (AC28) | Reply |
| A | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| B | STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
| C | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
SPCL*GSPECIAL TEST FEATURES
TEST CONDITIONS AND RATINGS OR ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS THAT ARE DIFFERENT, MORE CRITICAL, OR MORE SPECIFIC THAN THOSE SPECIFIED IN A GOVERNING TEST DATA DOCUMENT.
Enter the reply in clear text.
(SPCLGSELECTED AND TESTED FOR NAVIGATIONAL SYSTEMS*)
ZZZK*JSPECIFICATION/STANDARD DATA
THE DOCUMENT DESIGNATOR OF THE SPECIFICATION OR STANDARD WHICH ESTABLISHED THE ITEM OF SUPPLY.
Enter the applicable Reply Code from the table below, followed by the Commercial and Government Entity (CAGE) Code of the entity controlling the document, a dash, and the document designator. The agency that controls the limited coordination document must be preceded and followed by a slash following the designator. The word canceled or superseded must be preceded and followed by a slash for the designator. Professional and industrial association specifications/standards are differentiated from a manufacturer's specification in that the data has been coordinated and published by the professional and industrial association. Include amendments and revisions where applicable.
(ZZZKJT81337-30642B*;ZZZKJS81349-MIL-D-180 REV1/CANCELED/*;ZZZKJP80205-NAS1103*;ZZZKJS81349-MIL-C-1140C/CE/*;ZZZKJT81337-30642B$$JP80205-NAS1103*)
| Table 1 |
| Reply Code (AN62) | Reply |
| V | FEDERAL MOTOR VEHICLE SAFETY STANDARD |
| F | FLAMMABILITY STANDARD |
| S | GOVERNMENT SPECIFICATION |
| T | GOVERNMENT STANDARD |
| U | INTERNATIONAL STD/SPEC |
| D | MANUFACTURERS SOURCE CONTROL |
| R | MANUFACTURERS SPECIFICATION |
| N | MANUFACTURERS SPECIFICATION CONTROL |
| M | MANUFACTURERS STANDARD |
| B | NATIONAL STD/SPEC |
| A | PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION |
| P | PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
If the specification/standard cited in reply to MRC ZZZK is nondefinitive, reply to MRC ZZZT. This reply is the data which is not recorded in Segment C.
ZZZT*JNONDEFINITIVE SPEC/STD DATA
THE NUMBER, LETTER, OR SYMBOL INDICATING THE TYPE, STYLE, GRADE, CLASS, AND THE LIKE OF AN ITEM IN A NONIDENTIFYING SPECIFICATION OR STANDARD.
Enter the applicable Reply Code from the table below followed by the appropriate number, letter or symbol.
(ZZZTJTY1*; ZZZTJTY1$$JSTA*; ZZZTJTY1$JSTA*)
| Table 1 |
| Reply Code (AD08) | Reply |
| AL | ALLOY |
| BE | ANNEALED |
| AN | ANNEX |
| AP | APPENDIX |
| AC | APPLICABILITY CLASS |
| AR | ARRANGEMENT |
| AS | ASSEMBLY |
| AB | ASSORTMENT |
| BF | BOND |
| BX | BOX |
| CY | CAPACITY |
| CA | CASE |
| CT | CATEGORY |
| CF | CIRCUMFERENCE |
| CL | CLASS |
| CE | CODE |
| CR | COLOR |
| CC | COMBINATION CODE |
| CN | COMPONENT |
| CP | COMPOSITION |
| CM | COMPOUND |
| CD | CONDITION |
| AV | CONFIGURATION |
| CS | CONSTRUCTION |
| BG | CORE CONDITION |
| CB | CUT OFF |
| AM | DELAY CLASS |
| DE | DESIGN |
| DG | DESIGNATOR |
| DW | DRAWING NUMBER |
| DU | DUPLEX |
| EG | EDGE |
| EN | END |
| FY | FAMILY |
| FG | FIGURE |
| AK | FILE NUMBER |
| FN | FINISH |
| FB | FLAVOR |
| BH | FLUX PERCENTAGE |
| FM | FORM |
| FA | FORMULA |
| AJ | GAGE STOCK NUMBER |
| GR | GRADE |
| GA | GRADUATION |
| AX | GRANULES |
| AY | GRIT |
| GB | GROUND |
| GP | GROUP |
| HA | HEAVY DUTY |
| BA | IMAGE COLOR |
| NS | INSERT |
| TM | ITEM |
| KD | KIND |
| KT | KIT |
| LG | LENGTH |
| LV | LEVEL |
| LT | LIMIT |
| MK | MARK |
| AA | MARKER |
| AD | MASK APERTURE |
| ML | MATERIAL |
| BB | MAXIMUM DENSITY |
| TA | MEDIUM TEMPER |
| MH | MESH |
| ME | METHOD |
| BC | MINIMUM DENSITY |
| MD | MODEL |
| MT | MOUNTING |
| AQ | NATURAL |
| AU | NON-DELAY CLASS |
| NR | NUMBER |
| BL | OUTFIT NUMBER |
| PA | PARAGRAPH |
| PT | PART |
| PN | PATTERN |
| PC | PHYSICAL CONDITION |
| PS | PIECE |
| PL | PLAN |
| PR | POINT |
| PD | POLISHED |
| PB | PRESSURE RATING |
| QA | QUALITY |
| QB | QUENCHED |
| RN | RANGE |
| AE | RAPID |
| RT | RATING |
| RF | REFERENCE NUMBER |
| RA | REGULAR DUTY |
| BJ | RMA FLUX |
| SJ | SALIENT CHARACTERISTICS |
| SC | SCHEDULE |
| SB | SECTION |
| SL | SELECTION |
| BD | SERIALIZED |
| SE | SERIES |
| SV | SERVICE |
| SX | SET |
| SA | SHADE |
| SH | SHAPE |
| SG | SHEET |
| SZ | SIZE |
| AG | SLOW |
| TC | SOFT TEMPER |
| SK | SOURCE |
| PZ | SPECIES |
| SQ | SPECIFICATION SHEET |
| SD | SPEED |
| AW | STANDARD |
| SR | STRAIGHT |
| ST | STYLE |
| SS | SUBCLASS |
| SF | SUBFORM |
| SP | SUBTYPE |
| BK | SUPPORT |
| SN | SURFACE CONDITION |
| SY | SYMBOL |
| SM | SYSTEM |
| TB | TABLE |
| TN | TANNAGE |
| TP | TEMPER |
| TX | TEXTURE |
| TK | THICKNESS |
| TT | TREATMENT |
| TR | TRIM |
| TY | TYPE |
| YN | UNIT |
| AZ | UNSERIALIZED |
| VA | VARIETY |
| WT | WEIGHT |
| WD | WIDTH |
ZZZY*GREFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS
A FEATURE OF THE ITEM OF SUPPLY WHICH MUST BE SPECIFICALLY RECORDED WHEN THE REFERENCE NUMBER COVERS A RANGE OF ITEMS.
Enter the reply in clear text.
(ZZZYGCOLOR CODED LEADS*; ZZZYGAS DIFFERENTIATED BY MATERIAL*)
Reply to this requirement only if the header record for the item identification for the item being identified has been coded as critical.
CRTL*ACRITICALITY CODE JUSTIFICATION
THE MASTER REQUIREMENT CODES OF THOSE REQUIREMENTS WHICH ARE TECHNICALLY CRITICAL BY REASON OF TOLERANCE,FIT,PERFORMANCE,OR OTHER CHARACTERISTICS WHICH AFFECT IDENTIFICATION OF THE ITEM.
Enter the Master Requirement Code for the requirement, the reply to which renders the item as being critical.
(CRTLAAKJA*; CRTLAAKJA$$ACSGS*)
If document availability code B, D, F, OR H, reply to MRC PRPY.
PRPY*APROPRIETARY CHARACTERISTICS
IDENTIFICATION OF THOSE CHARACTERISTICS INCLUDED IN THE DESCRIPTION FOR WHICH A NON-GOVERNMENT ACTIVITY HAS IDENTIFIED ALL OR SELECTED CHARACTERISTICS OF THE ITEM AS BEING PROPRIETARY AND THEREFORE RESTRICTED FROM RELEASE OUTSIDE THE GOVERNMENT WITHOUT PRIOR PERMISSION OF THE ORIGINATOR OF THE DATA.
Enter the MRC codes of the individual characteristics of the description which are marked proprietary on the technical data, using and coding ($) for multiple characteristics. If all the MRCS are proprietary, enter the reply PACS. If none of the MRCS is proprietary, enter the reply NPAC.
(PRPYAPACS*;PRPYANPAC*; PRPYAMATL$$ASURF*)
ELRN*GEXTRA LONG REFERENCE NUMBER
A REFERENCE NUMBER EXCEEDING 32 POSITIONS.
Enter the entire reference number. Do not include the 5-position Commercial and Government Entity (CAGE) Code unless there is more than one extra long reference number on the NSN.If there is more than one extra long reference number on the NSN, include the CAGE or NCAGE and separate each reference by using the "&" character.
(e.g., CAGE112036BIL060557LEN313605UZ62365 & CAGE112036BIL060557LEN313605UZ62365)
In determining quantity of characters in the reference number, count will be made after modification in accordance with Volume 2, Chapter 9, FLIS Procedures Manual, DoD 4100.39-M.
NHCF*DNUCLEAR HARDNESS CRITICAL FEATURE
AN INDICATION OF THE NUCLEAR HARDNESS CRITICALITY OF THE ITEM.
Enter the applicable reply code from the table below
(NHCFDCY)
| Table 1 |
| Reply Code (AD05) | Reply |
| CY | HARDENED |
AFUA*JELECTRICAL POWER RATING AT MAXIMUM DC VOLTAGE RATING
A MEASURE OF THE DIRECT CURRENT POWER HANDLING CAPABILITY OF AN ITEM.
Enter the applicable Reply Code from Table 1 below followed by a numeric reply with a minimum of one digit, a decimal and a minimum of one digit.
(AFUAJW2.0*)
| Table 1 |
| Reply Code (AC33) | Reply |
| H | HORSEPOWER |
| E | VOLT-AMPERE |
| W | WATTS |
Reply to this MRC in accordance with Volume 3.
AGAV*GEND ITEM IDENTIFICATION
THE NATIONAL STOCK NUMBER OR THE IDENTIFICATION INFORMATION OF THE END EQUIPMENT FOR WHICH THE ITEM IS A PART.
Enter the reply in clear text.
(AGAVG3930-00-000-0000*; AGAVGFORKLIFT TRUCK, SMITH CORPORATION, MODEL 12, TYPE A*)
PMLC*JPRECIOUS MATERIAL AND LOCATION
AN INDICATION OF THE PRECIOUS MATERIAL AND ITS LOCATION IN THE ITEM.
Enter the applicable Reply Code from Table 1 below followed by a alpha-numeric reply with a minimum of one character.
(PMLCJRTA0002.0*;PMLCJRTA0002.0$JRTA0002.0*;PMLCJRTA0002.0$$JRTA0002.1*)
| Table 1 |
| Reply Code (MA01) | Reply |
| AUA000 | GOLD |
| IRA000 | IRIDIUM |
| AZA000 | OSMIUM |
| PDA000 | PALLADIUM |
| PTA000 | PLATINUM |
| RHA000 | RHODIUM |
| RTA000 | RUTHENIUM |
| AGA000 | SILVER |
CXCY*GPART NAME ASSIGNED BY CONTROLLING AGENCY
THE NAME ASSIGNED TO THE ITEM BY THE GOVERNMENT AGENCY OR COMMERCIAL ORGANIZATION CONTROLLING THE DESIGN OF THE ITEM.
Enter the reply in clear text.
(CXCYGLINE PROCESSOR CONTROL BOARD*)
CLQL*GCOLLOQUIAL NAME
A COMMON USAGE NAME BY WHICH AN ITEM IS KNOWN.
Enter the reply in clear text.
(CLQLGWOVEN WIRE CLOTH*)